Takeda, Takeshi
JAEA-Data/Code 2016-004, 59 Pages, 2016/07
The TR-LF-07 test simulated a loss-of-feedwater transient in a PWR. A SI signal was generated when steam generator (SG) secondary-side collapsed liquid level decreased to 3 m. Primary depressurization was initiated by fully opening a power-operated relief valve (PORV) of pressurizer (PZR) 30 min after the SI signal. High pressure injection (HPI) system was started in loop with PZR 12 s after the SI signal, while it was initiated in loop without PZR when the primary pressure decreased to 10.7 MPa. The primary and SG secondary pressures were kept almost constant because of cycle opening of the PZR PORV and SG relief valves. The PZR liquid level began to drop steeply following the PORV full opening, which caused liquid level formation at the hot leg. The primary pressure became lower than the SG secondary pressure, which resulted in the actuation of accumulator (ACC) system in both loops. The primary feed-and-bleed operation was effective to core cooling because of no core uncovery.
Kukita, Yutaka; Tasaka, Kanji
Natural Circulation in Single-Phase and Two-Phase Flow, p.77 - 83, 1989/00
no abstracts in English
C.P.Fineman*; ; Tasaka, Kanji
JAERI-M 83-088, 50 Pages, 1983/06
no abstracts in English